Always believing in new developments & changes for positive purpose, the sunray may have various characteristics like - Manufactured and fabricated from high grade of material under qualified engineers’ inspection at its own factory.
- 100 % GE SILICONE SEALANT along the frame bottom and corners.
- Storage Tank for 800/ 1000/ 1200/ 1500/ 2000/ 2500/ 3000 Liters Capacity
Key Technical Details for System InstallationRequire Area- 2 Sq meters / 100 liters,
- Bright sunshine is necessary between 9 a.m. & 4 p.m. to get optimum results.
Ideal Water: Less than 150-ppm total hardness. Roof Loading Requirements: 40 kg / collector spread over 2 Sq. meter area, 1200 kg / 1000 liters of storage tank, spread over 2-3Sq. meters area 3600 Kg / 3000 liters of storage tank, spread over 3 – 4 Sq. meters. Over Head Tank – The Minimum Height- Domestic Systems: 1.8 Mtr. From bottom of the tank.
- Industrial Systems: 3-4 Mtr. From bottom of the tank.
Temperature Range: 60 c to 85 c. (Depends upon availability of solar radiations) The Capacity- Domestic: 25 liters/day/person.
- Industrial: 500-3000 liters / day thermosyphon, 3000 liters / day to any capacity – Forced flow.
Usage- Bathing
- Washing and Cleaning
- Boiler feed
- Industrial canteens
- Industrial processing
- Swimming pool heating etc.
- Hospitals, hostels, hotels, etc.
Key Technical Details for Flat Plate Solar (FPC)
Collector (flate Plate Solar Collector)
| Absorber material |
Copper 0.27 mm of 99.9% min, IS 191 (Part 8): 1980 |
| Absorber coating |
Selective coating. Absorptivity > 0.96 Emissivity < 0.2 |
| Riser |
Copper tube of dia 12.5 mm, Thickness 0.56mm (24 SWG) |
| Header |
Copper tube dia 25mm, Thickness 0.71mm(22 Swg) |
| Bonding between Riser & Header |
Silver brazing |
| Bonding between Fin & Tube |
Ultra sonic / continuous welding |
| End Connection |
63 mm dia G.I flanges (4mm thickness) |
| Collector box |
100mm x 25 mm, our own design Aluminum Section With coating (18Swg) |
| Collector bottom sheet |
Aluminum / coated mild steel sheet 0.71mm with silver Paint coating. |
| Back insulation |
50mm Thick Resin bonded synthetic cera wool. |
| Side insulation |
25mm Thick Resin bonded synthetic cera Wool. |
| Glazing |
Toughened glass, 4mm thickness, Transmissivity 88.8% at near normal incidence. |
| Glazing Retainer |
Unique Proprietary Aluminum Retainer. |
| Glass bending, Gasket |
EPDM to withstand temperature 125 c, without allowing moisture entry. |
Calculation of Energy & Amount Saved On FPC
1 person = 1 bucket of hot water (Minimum) (about 20 liter) per day (600C) 1 bucket of hot water = 1 unit (minimum) of electricity = 1 KWh = Rs. 4.50 So, 5 persons = 5 unit per day = 5 x Rs.4.50/- = Rs. 22.5/- per day Savings after 1 year = 300 days x Rs.22.5/- = Rs.6750/- per year
(Below results are achieved by various practicals and testings done by us. Results may alter at different conditions, so no guarantee for above figures)
| Capacity In LPD(Properties) |
1050 |
1500 |
2000 |
3000 |
| Cold Water Temperature |
250C |
250C |
250C |
250C |
| Hot Water Temperature |
600C |
600C |
600C |
600C |
| Difference In Temperature |
350C |
350C |
350C |
350C |
| Energy From Sunray Solar Heater (Capacity x Temp Difference)(K. Cal.) |
35000 |
52500 |
70000 |
105000 |
| Electricity Saved Per Day By Sunray |
40.7 |
61.0 |
81.2 |
122.1 |
| Annual Saving Of Electricity(Rs 4/Unit) 300 Days |
48840 |
73320 |
97440 |
146520 |
| After 10 Years Total Saving |
488400 |
733200 |
974400 |
1465200 |
|